Monitor is a kind of commonly used medical equipment, which has been seen in hospitals or various movies and TV programs even if it has not been used. After use, the patient's physical condition can be monitored effectively and in real time. If abnormal physiological parameters appear, an alarm will appear, so that doctors can know the patient's condition at any time. If such important medical equipment is operated incorrectly, serious problems will occur, so it is necessary to use it according to the specifications when operating. So how to use the monitor correctly?


1. Keep your skin clean and dry


First of all, patients who are ready to use the monitoring equipment should keep their skin clean and dry. At the position where the electrode patch needs to be placed, it is necessary to wipe off the cuticle of local skin with abrasive paper according to the situation, then clean it with clear water, and then wipe off all the water stains on the skin surface. After confirming that there is no moisture on the skin surface, take out the electrode patch of the monitoring equipment and stick it on the newly wiped part.


2. Connect the lead wire correctly


The lead wire is an important component to connect the patient's body with the monitor, so it must be connected correctly. After taking out the lead wires, first buckle the three lead wires into the ECG electrode patch, put the red electrode one finger below the right clavicle, put the yellow electrode at the midpoint of the two nipples, and put the black electrode at the intersection point between the left fifth rib and the left axillary front line. Then insert the other end plug of the ECG lead wire into the monitoring equipment correctly along the direction of the arrow. At this time, ECG monitoring can be performed by turning on the monitoring equipment.


Now, not only hospitals, but also some old-age care institutions and some patients at home will use monitoring equipment. However, only by using the monitor correctly can it play its due role, and various physiological parameters displayed in the monitoring equipment will be correct and have reference significance. Therefore, it is very important to operate and use the monitoring equipment correctly. Monitor manufacturer, EEG machine, Meilun