91精品日韩人妻无码久久不卡-8050免费午夜一级国产精品-国产精品推荐天天看天天爽-亚洲中文字幕无码爆乳av中文

Wechat QR code

監(jiān)護(hù)儀廠家,腦電圖機(jī),美倫,美倫醫(yī)療電子有限公司

TEL:400-654-1200

Meilun Medical

Stock code 871562

Phone:

400-654-1200

What do you want to know?

監(jiān)護(hù)儀廠家,腦電圖機(jī),美倫,美倫醫(yī)療電子有限公司
Current position: Homepage >> News >> Company news

The monitor is described

The number of clicks:
Release date: 2016-12-13 00:00:00
Source: Henan Meilun Medical Electronics Co., Ltd.
share it
Monitor factory to monitor is described:
1, the use of the most accurate world famous module
2, the waveform is the most clear, it USES the 8.4 -inch color LCD TEF has strong brightness and high resolution.
3, the operation of the hook, and the screen can be used in both Chinese and English and Chinese, as a result, it is very easy to learn and operate.
4, you can at the same time
5, display ECG, ECG waveform can be replayed, every five minutes and part of the ST check itself.
6, which they can capture mobile memory data and waveforms
7, can set the alarm limit, as well as sound and light alarm.
8, it can be used for adults, children, and the new born baby.
9, it is an electric knife
10, it is widely used in internal medicine, surgery, obstetrics, gynecology, pediatrics, first aid, ICU, CCU
Fetal heart rate:
Probe: nine chips, beam width, pulse, high sensitivity
Ultrasonic power less than 1 mw/cm2
Its working frequency: 1.0 MHZ
How to deal with the signal, digital signal processing unit
Maximum audio output power: 1.5 W
Shrinkage stress:
Measuring range: 20 ~ 100 pressure unit
The probe ultrasonic output:
According to the rule set in 1992, the negative peak sound pressure should be less than 1 mpa, the strength of the beam and sound should be less than 20 MW/cm2, the instantaneous peak value of the average intensity of the sound should be less than 100 MW/cm2.The intensity of the sound, the display is less than 1 mw/cm2.
GEL:
Viscosity of water-based compound, not hurt the skin, not allergies, stability, resistance to bacteria.



Ecg monitoring considerations:
1. Remove the ecg cable, will lead wire plug convex on the host "ecg" jack grooves on the front panel, insert
2. 5 electrodes with ecg cable head connected with human being measured, on the other side of the connection of the right steps are:
A. five specific location in the human body brush try sand patches on the electrodes, and then use 75% ethanol to measure parts surface qing jie, purpose clear the cuticle and perspiration on the human skin, prevent electrode slice of poor contact.
B. to the electrode head and five electrode ecg cable electrodes on QQ.
C. ethanol volatilization after clean, 5 of electrodes will be posted on reliable contact with a specific position after cleaning, does not fall off.
D. will lead wire on the skirt clip in fixed beds is good.And told the patient and medical staff don't pull the electrode wire and lead wire.
Good, please be sure to connect ground wire, that would be the normal waveform display plays a very important role.
The monitor is described
91精品日韩人妻无码久久不卡-8050免费午夜一级国产精品-国产精品推荐天天看天天爽-亚洲中文字幕无码爆乳av中文